Skip to content Skip to footer

Tektronix(泰克) TDS210数字存储示波器

Characteristics

Signal Acquisition System

Bandwidth -

TDS210: 60 MHz

TDS220: 100 MHz

TDS240: 100 MHz

Sample Rate - 1 GS/s on each

channel

Channels -

TDS210 and TDS220: 2 identical

channels plus external trigger

TDS224: 4 identical channels

Sensitivity (with calibrated fine adjustment) - 2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div,

in all modes, and 20 MHz at 10 mV/div in Peak Detect mode)

Vertical Zoom - Vertically expand or compress a live or stopped

waveform

Calibrated Position Range

Volts/Div Setting

Offset Range

2 mV to 200 mV/div

±2 V

>200 mV to 5 V/div

±50 V

DC Gain Accuracy - ±3% (±4% at 2 mV/div and

5 mV/div)

Vertical Resolution - 8-bit (256 levels over

10.24 vertical divisions)

Automatic Measurements

Period,

frequency, cycle RMS, mean, peak-to-peak

Acquisition Modes

Sample, Average, Peak Detect - High frequency and random

glitch capture; captures glitches as narrow as 10 ns using acquisition

hardware at all time/div settings between 5 µs/div and 5 s/div

Time Base System (main and Window)

Horizontal Zoom

- Horizontally expand or compress a live or stopped waveform

Time/Division Range - 5 ns to 5 s/div

Record

Length - 2,500 sample points per channel

Horizontal

Accuracy - ±0.01%

Nonvolatile Storage

Waveform

Display - Two 2,500 point reference waveforms

Waveform

Storage -

TDS210 and TDS220: Two 2,500 point reference waveforms

TDS224: Four 2,500 point reference waveforms

Setups - 5 front panel setups

Triggering System (main

Only)

Trigger Type - Edge (rising or falling), video,

set to 50%

Video Trigger Type - Triggers on fields

or lines from composite video; triggers on broadcast standard NTSC,

PAL or SECAM video

Trigger Modes - Auto, normal, single

sweep

Trigger Source -

TDS210 and TDS220: CH1,

CH2, Ext, Ext/5 and AC Line

TDS224: CH1, CH2, CH3, CH4 and

AC Line

Trigger View - Displays trigger signal

while trigger view button depressed.

Cursors

Types

- Voltage, time

Measurements - Delta T, 1/Delta

T, Delta V

Waveform Processing

Arithmetic Operators

- Add, subtract

Sources - CH1±CH2, CH3±CH4 (TDS224)

Autoset - Single button automatic setup on selected input

signal for vertical, horizontal and trigger systems.

Display

System

Robust, backlit LCD with adjustable multilevel contrast.

Interpolation - Sin(x)/x

Display Modes - Vectors, dots

Persistence - Off, 1 sec, 2 sec, 5 sec,

infinite

Format - YT and XY

Hardcopy Capability

(requires Modules)

Printer/File Formats - Thinkjet,

Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411,

DPU 412

Hardcopy Layout - Landscape or portrait

TDS2CM Communications Extension Module

Centronics-type

Parallel Port

RS-232 Programmability - Full talk/listen

modes. Control of all modes, settings and measurements. Baud rate

up to 19,200. 9-Pin, DTE.

GPIB Programmability - Full

talk/listen modes. Control of all modes, settings and measurements

(IEEE Std 488-1987). Includes WaveStar™ Software for Oscilloscopes

30 day product demo.

TDS2MM Measurement Extension Module

FFT -

Windows: Hanning, Flat Top, Rectangular

Sample points: 2,048

Automatic Measurements - Rise/fall time, positive/negative pulse width

Interface

- Centronics, RS-232, GPIB

Environmental and Safety

Temperature -

Operating: 0°C to +50°C

Nonoperating:

-20°C to +60°C

Humidity -

Up to 90% RH at

or below +40°C;

Up to 60% RH from 41°C to 50°C (operating and

nonoperating)

Altitude - Up to 3,000 m (operating)

EMC - Meets Directive 89/336/EEC, GOST

Safety

- UL3111-1, CSA1010.1, IEC61010-1, EN61010-1

Physical

Characteristics

Dimensions

mm

in.

Weight

kg

lb.

Width

304.8

12.0

Height

151.4

5.96

Depth

120.7

4.75

Oscilloscope only

1.5

3.25

w/accessories

1.7

3.75

Copyright © 2088 世界杯八强_2018年世界杯亚洲区预选赛 - nprny.com All Rights Reserved.